Search results for " Fluoroscopy"
showing 5 items of 5 documents
Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers
2002
WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …
Interventistica eco-guidata per l’articolazione d’anca
2013
Lo scopo di questo lavoro è di rivedere le principali applicazioni della interventistica eco-guidata d’anca, descrivendone le indicazioni e la metodologia. L’ecografia è una metodica considerata sicura per i pazienti, in quanto non è stato dimostrato un possibile danno dovuto all’energia trasmessa dagli ultrasuoni ai tessuti del paziente, contrariamente alle metodiche che fanno uso di radiazioni ionizzanti, come la radiografia convenzionale e la tomografia computerizzata. Inoltre, l’ecografia risulta rapida ed efficace nel guidare l’ago verso la sede voluta evitando di intercettare strutture vascolari e/o nervose, consentendo quindi una maggiore sicurezza, rispetto alle tecniche interventis…
Ultrasonography utilization in forearm fractures at the emergency department
2019
Fully robotic Ivor–Lewis esophagectomy (RAMIE4) for esophageal cancer after emergency surgery and ligation of the gastroduodenal artery
2018
We report a case of a 69-year-old patient with esophageal cancer and severe upper gastrointestinal bleeding during neoadjuvant radiochemotherapy who required mass transfusion followed by complex emergency procedures. Despite endoscopic stenting, the bleeding recurred, and thus emergency open surgery was required. Gastric wedge resection of the minor curvature necessitated by perforation caused by the endoscopic stent maneuver and duodenotomy with ligation of the gastroduodenal artery, as the cause of persistent intraluminal bleeding, were performed. The already prepared gastric conduit during the emergency operation did not become ischemic, even though the gastroduodenal artery, left gastr…
Differences in Accuracy and Radiation Dose in Placement of Iliosacral Screws: Comparison between 3D and 2D Fluoroscopy
2022
Percutaneous iliosacral screw fixation is a widely accepted method of stabilizing the posterior pelvic ring. Recently developed tools such as 3D-navigated fluoroscopy and computed navigation seem to prevent a surgeon from conducting screw misplacement. The study aimed to comparatively assess the introduction of sacroiliac screw placement using 2D and 3D fluoroscopy in terms of accuracy and radiation exposure. Iliosacral screws were introduced in 37 patients using 2D (group N1) and in 36 patients using 3D fluoroscopy (group N2) techniques. Overall, 61 and 56 screws were introduced in groups N1 and N2, respectively. Screw placement accuracy was assessed using postoperative computed tomography…